期刊文献+

近红外无损伤脑血氧监测仪的研制——系统设计及实验验证 被引量:2

Development and Validation of Near-infrared Brain Blood-Oxygen Monitor
下载PDF
导出
摘要 我们设计并研制了一种脑血氧监测仪,利用近红外光谱检测生物组织血、氧含量的原理,实现了对双侧脑组织局部血、氧参数的同时检测。检测探头采用两个不同波长的超高亮LED作为光源,通过两个光电传感器分别接收经左右大脑组织散射后的光信号,实现双探头检测双侧脑组织局部血、氧参数检测的功能。而且检测探头的外型结构经过特殊设计,有效地抑止了外界环境噪声同时减小了固定检测探头时给病人带来的不适感。仪器同时输出两侧脑组织的血容量和氧含量曲线,可以实现对病人的双侧脑组织血、氧变化参数进行长时间实时、连续的监测。最后利用生物模型实验验证了仪器的有效性。 The main purpose of this paper is to describe the design and development of the near-infrared bloodoxygen monitor which is based on the theory of detecting the blood- oxygen parameters of tissue by near- infrared, and the monitor can detect the blood-oxygen parameters of two sides of the local brain tissue. The monitor uses two wavelength ultra-high light LED as lamp-house, and two sensors detect the light scattered by two sides of the local brain tissue, which make the monitor achieve the function of dual detector. The appearance of the monitor's detector is designed to reduce effectively the noise brought by the background and alleviate the discomfort feelings of the patient. At the same time, this apparatus can monitor continuously the brain blood- oxygen parameters of the patients in real time, and output the curves of the blood-oxygen and oxygen concentration of two sides of brain tissue. At last, the biological model experiments and the tests in clinial setting validate the monitor.
出处 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2007年第6期1220-1223,共4页 Journal of Biomedical Engineering
基金 武汉市科技型中小企业创新基金资助项目(武财[2005]84号)
关键词 近红外光 脑血氧 血容量 氧含量 Near-infrared spectroscopy Brain blood-oxygen Blood volume Oxygen concentration
  • 相关文献

参考文献12

  • 1王强,林淑娟,罗致诚.无创伤红外光谱脑血氧监测仪[J].国外医学(生物医学工程分册),1998,21(1):19-26. 被引量:6
  • 2Patterson MS, Wilson BC, Wyman DR. The propagation of optical radiation in tissue II: Optical properties of tissues and resulting fluence distributions. Lasers in Medical Science, 1991,(4) : 379.
  • 3Staveren HJ, Moes CJM, Van Marie J, et al. Light scattering in intralipid 10%in the wavelength range of 400-1100nm. Appl Opt, 1991,(30) :4507.
  • 4JObsis FF, Noninvasive infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science, 1977,(198) : 1264.
  • 5Roggan A, Dorschel K, Minet O. The optical properties of biological tissue in the near infrared wavelength range: review and measurements. Laser-induced Interstitial Thermotherapy, SPIE Press, 1995,10.
  • 6McCormick PW, Goetting MG, Stewart, et al. Comparison of near-infrared spectroscopy and EEG in detection of cerebral hypoxia. Crit Care Med, 1990,(4) : 203.
  • 7Koorn R, Silvay G, Weiss-Bloom L, et al. Evaluation of noninvasive optical spectroscopy during general anesthesia. Anesthesiology, 1991,(75) : 415.
  • 8Martin Wolf, Kurt von Siebenthal, et al. Comparison of three methods to measure absolute cerebral hemoglobin concentration in neonates by near-infrared spectrophotometry. J Biomed Opt, 2002,(2) : 221.
  • 9McCormick PW, Stewart M, Goetting MG, et al. Regional cerebrovascular oxygen saturation measured by optical spectroscopy in humans. Stroke, 1991,(22) : 596.
  • 10Gratton E, Fantini S, Franceschini MA, Gratton G, Fabiani M. Measurement of scattering and absorption changes in muscle and brain. Phil Trans R Soc Lond B, 1997,(352) : 727.

共引文献5

同被引文献15

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部