摘要
本文对两种分析方法进行了实验比较,分别测定了电子陶瓷用钛酸钡纳米粉体中钡钛的含量.硫酸钡重量法与铝还原法测定钡钛的标准偏差为0.047%和0.055%;且测定钛的准确度较高.络合滴定法测定钡钛的标准偏差为0.039%和0.049%;且测定钡的准确度较高,同时具有快速简便的特点.
Barium and Titanium in barium titanate electronic ceramic nanopowders are determined by two main chemical analysis methodsusing barium sulphate volumetric precipitation method and aluminum as reducing agent. RSD is 0.047% and 0.055%, high in determining accuracy for titanium were determined. Another one is determined with complexometric titrimetry. RSD is 0.039% and 0.049%, and high in determining accuracy for barium is determined.
出处
《西南民族大学学报(自然科学版)》
CAS
2007年第6期1361-1364,共4页
Journal of Southwest Minzu University(Natural Science Edition)
基金
四川省2003年重点科研项目资助(02G0099026).
关键词
纳米粉
电子陶瓷
钛酸钡
钡钛分析
nanopowerder
electron ceramic
Barium Titanate
analysis of Barium and Titanium