摘要
目的建立血浆中9-羟基利培酮(9-OH-RSP)异构体的测定方法。方法样品经液-液萃取后,采用ChiralAGP柱(100mm×4.0mm,5μm)进行分离,柱温为25℃,以50mmol·L^-1醋酸铵(pH6.5)-异丙醇(95:5)为流动相,流速为0.9mL·min。采用电喷雾电离源正离子模式(ESI^+),选择性离子监测(SIR)9-OH-RSP和内标安定的质荷比(m/z)分别为428和285的分子离子峰。结果9-羟基利培酮异构体在1.47~275.30μg·L^-1线性良好。左右旋异构体萃取回收率均〉80%,日内、日间RSD均〈15%。结论该方法准确、重现性好、灵敏度高,可用于测定血浆中9-羟基利培酮异构体的浓度。
Objective To develop a method for the determination of 9-hydroxyrisperidone enantiomers in the plasma. Methods After being pretreated by liquid-liquid extraction, the samples were separated by Chiral-AGP column at 25 ℃. The mobile phase was 50 mmol · L^-1 ammonium acetate (pH 6. 5) -isoprotanol (95 : 5, w/v) with the flow rate of 0. 9 mL · min^-1. The compound was ionized in the electrospray ionization (ESF-) ion source of the mass spectrometer and detected in the selected ion recording (SIR) mode with the m/z of 9-OH-RSP and I. S. of 428 and 285 respectively. Results The assay was linear from 1.47 to 275.30μg · L^-1 for each enantiomer of 9-hydroxyrisperidone. The absolute recovery for each enantiomer was larger than 80%. The intra day and inter-day variations were less than 15%. Conclusion The method is accurate, sensitive, reliable and suitable for the determination of 9-hydroxyrisperidone enantiomers in the human plasma.
出处
《中南药学》
CAS
2007年第6期491-493,共3页
Central South Pharmacy
关键词
9-羟基利培酮
手性异构体
手性拆分
9 hydroxyrisperidone
enantiomers
enantiomeric determination