注射用头孢唑肟钠的无菌检查方法学研究

Research on Sterile test of Ceftizoxime Sodium for Injection
下载PDF
导出
摘要 目的建立国产注射用头孢唑肟钠的无菌检查法。方法取供试品3.0g,用100ml 0.1%的无菌蛋白胨溶液(pH7.1±0.2)溶解,采用薄膜过滤法,控制吸引器泵压为不大于0.012Mpa。冲洗液为0.1%的无菌蛋白胨溶液(pH7.1±0.2),冲洗量1200ml,冲洗完毕取出滤膜分3等份,浸泡于6mlβ-内酰胺酶中20分钟,取出滤膜放于培养基中按规定进行培养,以大肠埃希菌为阳性对照菌。结果本品的该检验用量在该检验条件下无抑菌作用。结论采用薄膜过滤法可进行国产注射用头孢唑肟钠的无菌检查。 Objective: To establish domestic Ceftizoxime Sodium for Injection Sterile test. Methods: take 3.0 g sample, dissolve with 100 ml of 0.1% sterile peptone solution (pH 7.1± 0.2),membrane filtration,pump pressure for not more than 0.012 MPa. Rinse with 1200ml 0.1% of sterile peptone solution (pH7.1 ±0.2), take the membrane, and separate in three equal parts, soaking in 6 ml beta-lactamase for 20 minutes, take out the membrane and keep it in the medium cultivate in accordance with the regulations, using E. coli bacteria as a positive control. Results: The test of the goods used in the testing has no inhibitory effect. Conclusion: membrane filtration method can be used for the sterility test of domestic Ceftizoxime Sodium for Injection.
作者 陈光 姚永年
出处 《泰州职业技术学院学报》 2007年第6期54-56,共3页 Journal of Taizhou Polytechnic College
关键词 注射用头孢唑肟钠 无菌检查(薄膜过滤法) 方法验证 Ceftizoxime Sodium for Injection sterility test (membrane filtration method) method validation