电站锅炉膜式水冷壁温度场特性的数值计算 被引量:3

Calculation of membrane waterwall temperature fields in power plant boilers
下载PDF
导出
摘要 建立了电站锅炉膜式水冷壁温度场二维稳态计算模型,采用有限容积法建立离散方程,编制求解流体换热和管壁导热耦合决定的锅炉膜式水冷壁二维温度场导热反问题数值计算程序。利用程序计算分析了1000MW超超临界锅炉垂直管圈膜式水冷壁的温度分布特性,计算结果可以很好地反映水冷壁管壁及鳍片温度分布规律,同时计算收敛性良好。计算结果表明,不同负荷率下,膜式水冷壁截面炉膛向火侧温度最高,在低负荷时管壁向火侧外壁温度最高,而高负荷时向火侧鳍端温度最高。 Two-dimensional calculating model and programs of membrane waterwall termperature fields in plant boilers are created. Based on finite volume method ( FVM ) the discrete - equations and the program of membrane waterwall termperature fields are carried out to calculate the inverse heat conduction problems of two-dimensional temperature fields affected by the fluid convection and the wall conduction. It is used in calculations for membrane waterwall temperature fields in the 1000 MW ultra-supercritical pressure once-through boiler. The simulation results agree well with the distributing law of membrane waterwall termperature fields in plant boilers, and good computing convergence is obtained. According to the calculating results,the highest temperature of membrane waterwall occurs at the flame facing ring end under high load, but it occurs at the outer water wall tube of flame facing side under low load.
出处 《水利电力机械》 CAS 2007年第12期23-27,共5页 Water Conservancy & Electric Power Machinery
基金 华北水利水电学院高层次人才启动项目 华北水利水电学院校青年基金(HSQJ2006003)资助
关键词 电站锅炉 膜式水冷壁 温度场 plant boilers membrane waterwall termperature fields
  • 相关文献

参考文献2

  • 1JAN TALER. A method of determining local heat flux in boiler furnaces [ J ]. Heat Mass Transfer, 1992,35 (6) : 1625 - 1634.
  • 2盛春红.超临界和近临界压力区垂直上升及倾斜管传热特性研究[D].西安:西安交通大学,1994.

共引文献2

同被引文献25

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部