针对当前燃油燃烧器配风合理控制等问题,提出了使用一个调风板或不使用调风板直接由风机控制通风总量,各部分风量由结构保证的设计方法。分析结果表明,该方法使得配风量控制简单化,实现了合理配风。
As to most of the traditional oil eombustor air supply is difficult to reasonable control. We proposed a design method that using an adjusting wind board controls aeration total amount, or using fan controls aeration total amount without adjusting wind board, each part of aeration amount is ensured by the structure of eombustor. It has been proved by our analysis that this method makes the control of air supply amount simple and air supply reasonable.
出处
《现代制造技术与装备》
2007年第6期23-24,共2页
Modern Manufacturing Technology and Equipment
关键词
燃烧器
配风
配风量
combustor, air supply, air supply amount