期刊文献+

围术期呼吸力学连续气道监测的研究 被引量:7

Continuous airway monitoring of respiratory mechanics during operation
原文传递
导出
摘要 目的:探讨围术期连续气道监测(CAM)的作用及成人、小儿异常通气的特点。方法:采用旁气流(SSS)技术以DatexUltimaSV/V监测仪,用D-lite管(9.0×1.5cm或7.2×1.2cm)行CAM,观察202例(ASAⅡ~Ⅳ)手术患者,年龄2~89岁,体重9~85kg;记录不同模式通气时CAM的各种参数或图像。结果:(1)CAM在人工通气患者中异常情况的检出率达11.4%;其中临床医师未发现,CAM首先显示异常情况达69.6%;与同类手术未用CAM相比有明显差异(P<0.01);(2)异常通气时CAM中PV环和FV环的变化特点小儿和成人一样。结论:CAM对了解成人和小儿麻醉和手术对肺和气道力学的相互影响,对通气异常的诊疗,对减少并发症提高围术期患者的安全性起着积极地作用。 Objective:To investigate the effects of continuous airway monitoring(CAM) in airway mechanics and the characteristics of abnormal ventilation in adult and paediatric.Method:202 patients(ASA grade Ⅱ Ⅳ)were observed with technique of side stream spirometer(SSS)during operation,whose ages were ranged from 2 to 89 years old and weights were varied from 9 to 85 kg.All parameters and illustrations of various modes of mechanical ventilation were recorded with Datex Ultima SV/V monitor,the D liter tube with different sensors:9.0×1.5 cm tube used in adults and 7.2×1.2 cm tube in paediatrics.Result: The detected rate of abnormal mechanical ventilation was 11.4% by CAM,of which 69.6% was undiscovered by the doctor.The safty of the patients with CAM was increased more than that of the patients without CAM during mechanical vantilation.There was significant difference in the rate between patients with CAM and without CAM(P<0.01);The changes of pressure volume loop and flow volume loop in adults and paediatrics were similar.Conclusion:The CAM is such a effective and optional monitoring technique as to improve the diagnosis and treatments,eliminate the complications,and enhance the safty of the patients during the operation.
出处 《中华麻醉学杂志》 CAS CSCD 北大核心 1997年第7期395-397,共3页 Chinese Journal of Anesthesiology
基金 广州市科委重点科研资助
关键词 旁气流 呼吸力学 连续气道监测 成人 小儿 Side stream spirometry Continuous airway monitoring Respiratory mechanics Adult Child
  • 相关文献

参考文献1

  • 1黄象谦,内科临床与新进展,1993年,78页

同被引文献60

  • 1陈锡明,周泓,朱明,张瑞东,黄延辉.三指宽度法选择小儿喉罩型号[J].上海第二医科大学学报,2005,25(10):1067-1069. 被引量:12
  • 2Alliaume B, Coddens J, Deloof T. Reliability of auscultation in positioning of double-lumen endobronchial tubes.Can J Anaesth, 1992,39 : 687-690.
  • 3Boudreault D,Brasseur L, Samii K, et al . Comparison of continuous epidural bupivacaine infusion plis either continuous epidural or patient-controlled epidural infusion of fentanyl for postoperative analgesia [J]. Anesth Analg, 1991 ,73(3) : 132~ 137
  • 4Glass PSA ,Esto KP, Giusberg B, et al . Use of patientcontrolled analgesia to compane the fficacy of epidural to intravenous fentanyl adminstration[J] .Anesth Analg , 1992 , 74(8): 345- 351
  • 5Hennis HH.Receptor bindng . Anaigesia and antitussive potency of tramadol and othe selected opioids . Arzneim forsch [J]. Drug Res , 1998 ,38(9) : 877-881
  • 6Naji P .Farsch-Schian M. Epidural droperidol and morphine for postoperative Pain[J]. Anesth Analg, 1990,70(6):583- 588
  • 7Huffman LM. New technologies inanesthesia: Update for nurse anesthetists - monitoring ventilation and compliance withSide Stream Spirometry. AANA Journal Course 1991,59(3) :249- 258.
  • 8Kytta J, Randell T, Tanskanen P et al. Monitoring lung compliance and end tidaloxygen content for the detection of venous air embolism . Br J Anaesth 1995,75(4) :447 -451.
  • 9Oikkonen M, Tallgren M. Changes in respiratory compliance at laparoseopy:measurements using side strean spirometry . Can J Anaesth 1995,42(6) :495 - 497.
  • 10Thorsteinsson A, Larsson A, Jonmarker C et al. Pressure - volume relations of therespiratory system in healthy children. American Journal of Respiratory and Critical CareMedicine 1994, 150:421.

引证文献7

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部