沙角A电厂锅炉炉膛安全监控系统(FSSS)没有在线逻辑试验功能。为了保证机组更安全地运行,进行了炉膛安全监控系统中总燃料跳闸停炉保护回路的在线试验方案设计。以沙角A电厂200MW机组为例,对总燃料跳闸保护逻辑进行了分析,设计了总燃料跳闸保护输入和输出回路的在线试验方案,论证方案的可行性及存在的风险。增加在线试验系统后,可在机组运行中随时在线检验总燃料跳闸保护回路输入-输出通道的可靠性,满足机组安全性评价的要求。
The furnace safety supervisory systcm (ESSS) in Shajiao A Power Station lacks the function of on-line logic test. To further ensurc the safety of the units, an on-line test schemc is designed for the protectivc circuit of master fuel trip (MFT) in the FSSS. Taking the 2{}0 MW units in Shajiao A Power Station for example, an analysis is made of the MFF protective logic, and an on-line test schemc is designed for MFT protective input and output circuit. The feasibility and possible risks thereof are demonstrated, After adding the on-line test system, the reliability of the input/output channels of MFF protective circuit can be checked on line at any moment in thc operation of the units, which meets the requirements of unit safety evaluation.
出处
《广东电力》
2007年第12期47-50,共4页
Guangdong Electric Power
关键词
炉膛安全监控系统
总燃料跳闸
保护回路
在线试验
furnace safety supervisory system (FSSS)
master fuel trip (MFF)
protective circuit
on-line test