期刊文献+

毛细管柱固定抗原流动注射化学发光免疫法测定IgG

Flow injection chemiluminescent immunoassay determination of IgG using antigen-immobilized capillary column
下载PDF
导出
摘要 目的 建立基于毛细管柱固定抗原流动注射增强化学发光免疫法测定IgG分析的新方法。方法以辣根过氧化物酶(HRP)标记抗IgG与抗IgG竞争毛细管内壁表面固定的IgG抗原,利用HRP催化对鲁米诺-过氧化氢-对碘苯酚体系的增强化学发光,建立测定IgG的流动注射化学发光免疫分析方法。结果在选定的实验条件下,化学发光信号与IgG在稀释比为1:1×10^11-1:1×10^10间成良好的线性关系,相关系数为0.9960。对稀释比为1:5×10^10 IgG抗体连续11次测定的相对标准偏差为6.5%。结论将该法应用于合成血清样品中IgG抗体的测定,结果满意。 Aim To study a novel method for the determination of anti-IgG. Methods A flow injection chemilumineseent (CL) immunoassay using an antigen-immobilized capillary column as reactor was developed. When the sample (anti-IgG) and the HRP-labeled anti-IgG passed through the reactor, a competitive binding for IgG antigen immobilized on the wall oeeured and the different CL intensity generated from the system of luminol-hydrogen peroxide-p-iodophenol in the presence of HRP was produced in the dependence of the concentration of anti-IgG. Results The linear range of anti-IgG from the dilution of concentration 1:1 × 10^11 to 1: 1 × 10^10 with a relative standard deviation of 6. 5% is obtained using the system designed. Conclusion This developed method has been applied to the determination of anti-IgG in human control serum with satisfactory results.
出处 《西北大学学报(自然科学版)》 CAS CSCD 北大核心 2007年第6期996-999,共4页 Journal of Northwest University(Natural Science Edition)
基金 陕西省自然科学基金资助项目(2001H17)
关键词 流动注射分析 免疫分析 化学发光 毛细管柱 IGG flow injection analysis chemiluminescence immunoassay capillary column anti-IgG
  • 相关文献

参考文献8

  • 1WHITEHEAD T P, THORPE G H G, CARTER T J N, et al. Enhanced Luminescence procedure for sensitive determination of peroxidase-labeled conjugates in immunoassay [ J]. Nature, 1983,305 : 158-159.
  • 2封满良,章竹君,张新荣.增强化学发光酶免疫分析法测定血清中的铁蛋白[J].分析化学,1994,22(8):788-790. 被引量:5
  • 3宋正华,吕继宏,王林,赵铁柱.高选择性流通式五倍子酸传感器的研究(英文)[J].西北大学学报(自然科学版),2001,31(3):215-219. 被引量:1
  • 4骆建新,郑崛村,王伦安,李晋川,邱岳,伍莉萍,杨秀岑.流动注射协同增强化学发光免疫分析法的建立与评价[J].分析化学,2002,30(7):792-796. 被引量:3
  • 5MATSUNAGA T,KAWASAKI M, YU X, et al. Chemiluminescence enzyme immunoassay using bacterial magnetic particles[J]. Anal Chem,1996,68(20) :3 551-3 554.
  • 6LIU H J,JIM C Y, DILBIR S B, et al. Flow injection solid- phase chemiluminescent immunoassay using a membrane - based reactor [ J ]. Anal Chem, 1991,63: 666- 669.
  • 7LIU Y Ch, LI Y B. An antibody-immobilized capillary column as a bioseparator/bioreactor for detection of Escherichia coli O157:H7 with absorbance measurement[ J]. Anal Chem,2001,73(21).5 180-5 183.
  • 8YAKOVLEVA J,DAVIDSSON R, LOBANOVA A, et al. Microfluidic enzyme immunoassay using silicon microchip with immobilized antibodies and chemiluminescence detection[J]. Anal Chem,2002,74(13) :2 994-3 004.

二级参考文献9

共引文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部