摘要
介绍了0~25mm数显千分表的示值误差测量结果的不确定度分析,表明了用TWIN—CHECK1200测长机进行校准的可行性。
The uncertainty evaluation of measuring results about indicator error of digital dial gauge 0 - 25 mm was analyzed in this article, those indicated that it was feasible using TWIN-CHECK1200 length measuring machine as calibration tools.