对烟气脱硫工程中设置烟气再热系统(GGH)进行了利弊分析,针对神头第二发电厂2×500 MW燃煤机组脱硫工程前期工作中,对是否加装GGH作了技术经济综合比较,并进行了环境影响评价分析。认为湿法脱硫工艺安装GGH弊多利少,省去GGH是可行且有利的,不设置GGH有显著的技术经济优势,得到了省环保部门的认可,为工程取消GGH提供了决策依据。
Advantage and disadvantage of GGH of limestong-gypsum program is analysed, based on the compredensive technique economy comparison of GGH , environment influence estimation is also proposed. As a result, wet flue gas desulfurization of GGH installation is better than its uninstallation which is full of technique economy advantage and gets consent of environmental protection section.
出处
《山西电力》
2007年第6期68-70,72,共4页
Shanxi Electric Power