摘要 通过室内土柱试验装置来模拟渭河渗滤系统,研究了苯胺污水在饱水渗滤系统中的迁移转化特征。结果表明,其迁移转化作用主要为苯胺的厌氧生物降解作用,其转化结果是饱水渗滤系统对苯胺污水有很大的净化作用,其净化率达到100%。 A river infiltration system was used for analysis of sewage purification effect through an experiment. It was shown that the system could make full use ofits purification function to treat the sewage. In the experiment, an indoor soil column device was used to simulate Weihe River's infiltration system.The simulating results showed the environmental behavior to be mainly adsorption action and biological degradation action. The purification action of the river infiltration system on aniline wastewater is obvious; its purification rate was as high as 100%.
出处 《水处理技术》 CAS CSCD 北大核心 2008年第1期34-36,68,共4页 Technology of Water Treatment
基金 中国地质调查局国土资源重大项目(1212010331302)
关键词 苯胺 渗滤系统 迁移转化 生物降解作用 aniline infiltration system migration and transformation biodegradation
  • 相关文献

参考文献4

  • 1Wolfgang kuehn,Uwe Mueller.Riverbank filtration-an overview[J]. Journal Awwa,2000(1):61-69.
  • 2Chittaranjan Ray,Thomas Grischek,Jurgen Schubert,et al.A perspective of riverbank filtration [J].Applied Science and Tech Plus, 2002,149-161.
  • 3C Ray,T W Soong,Y Q Lian,G S Roadcap.Effect of flood-induced chemical load on filtrate quality at bank filtration sites[J].Journal of Hydrology,2002(266):235-258.
  • 4Eckhard Worch, et al,Laboratory tests for simulating attenuation processes of aromatic amines in riverbank filtration [J].Journal of Hydrology,2002(266):259-2681