期刊文献+

比浊法自动测定乙酰螺旋霉素片的效价 被引量:1

Content determination of acetylspiramycin tablets by turbidimetric method
下载PDF
导出
摘要 目的建立比浊法测定乙酰螺旋霉素片的方法。方法金葡菌为实验菌,加菌量约0.5%(V/V),(37±0.5)℃培养3.5~4.5h测定。结果抗生素线性浓度为3.2~15.6μg/ml,平均回收率为100.7%(n=9),RSD=1.4%。结论本方法操作方便、快速,灵敏、可信限率低,结果准确,精密度好,可作为乙酰螺旋霉素片效价的测定方法。 Objective To establish a turbidimetric method for the content determination of acetylspiramycin tablets. Method The test organism was Staphylococcus aureus. Adjust the bacterial suspension of Staphylococcus aureus inoculation with about 0.5% (V/V) ratio, at (37±0. 5)℃ for 3. 5~4.5 hours. Results The linear range was 3. 2μg/ml~15.6 μg/ml and the average recovery was 100.7% (n=9); RSD=1. 4%. Conclusion The method was sensitive, rapid, precise and feasible for the determination of Acetylspiramycin tablets.
作者 刘英 崔春英
出处 《中国抗生素杂志》 CAS CSCD 北大核心 2008年第1期49-51,共3页 Chinese Journal of Antibiotics
关键词 效价 比浊法 乙酰螺旋霉素 Potency Turbidimetric method Acetylspiramycin tablets
  • 相关文献

参考文献6

二级参考文献7

  • 1张治锬.抗生素药品检验[M].北京:人民卫生出版社,1991.35.
  • 2周海钧 申蕴如.生物检定统计方法(第2版)[M].北京:人民卫生出版社,1988.50.
  • 3The United States Pharmacopeial Convention,Inc.The United States Pharmacopeial [S].Rochville MD:the United States Pharmacopeial Convention,In.,28th edu.:2256.
  • 4The British Pharmacopoeia Commission.The British Pharmacopoeia [S].London:the Stationary Office,2002:A259.
  • 5日本公订书协会.日本药局方XIV版[S].株式会社ビほう,2000:54.
  • 6胡昌勤 刘炜.抗生素微生物检定法及其标准操作[M].北京:气象出版社,1987,8..
  • 7姚尚辰,胡昌勤.琥乙红霉素效价测定中最佳水解条件的选择[J].药物分析杂志,2003,23(6):430-433. 被引量:8