期刊文献+

纳米颗粒在电化学生物传感器中的应用研究 被引量:3

下载PDF
导出
摘要 纳米技术介入生物传感器的研究领域具有非常重要的意义。简要介绍了电化学生物传感器的工作原理,着重讨论了纳米颗粒在电化学生物传感器中的研究进展,并论述了这一领域的发展趋势。
作者 刘阳
出处 《现代商贸工业》 2008年第2期281-282,共2页 Modern Business Trade Industry
  • 相关文献

参考文献7

  • 1任湘菱,唐芳琼.超细银-金复合颗粒增强酶生物传感器的研究[J].化学学报,2002,60(3):393-397. 被引量:48
  • 2[2]Xia Zhong,Ruo Yuan.,Yaqin Chai et al.Glucose biosensor based on self-assembled gold nanoparticles and double-layer 2d-network (3-mercaptopropyl)-trimethoxysilane polymer onto gold substrate[J],Sensors and Actuators B,2005,(104):191-198.
  • 3[3]Dawei Pan,Jinhua Chen,Shouzhuo Yao,et al.Amperometric glucose biosensor based on immobilization of glucose oxidase in electropolymerized o-aminophenol film at copper-modified gold electrode[J],Sensors and Actuators B,2005,(104):68-74.
  • 4[4]Shiyi Xu,Xiaozu Han:A novel method to construct a third-generation biosensor:self-assembling gold nanoparticles on thiol-functionalized poly(styrene co-acrylic acid) nanospheres[J],Biosensors and Bioelectronics,2004,(19):1117-1120.
  • 5钟霞,欧朝凤,邹建,袁若,柴雅琴.TiO_2纳米颗粒增强的过氧化氢生物传感器[J].西南大学学报(自然科学版),2007,29(5):40-43. 被引量:6
  • 6[6]Jingdong Zhang,Munetaka Oyama:A hydrogen peroxide sensor based on the peroxidase activity of hemoglobin immobilized on gold nanoparticles-modified ITO electrode[J],Electrochimica Acta,2004,(50):85-90.
  • 7[7]Songqin Liu,Zhihui Dai,Hongyuan Chen et al.Immobilization of hemoglobin on zirconium dioxide nanoparticles for preparation of a novel hydrogen peroxide biosensor[J]Biosensors and Bioelectronics,2004,(19):963-969.

二级参考文献22

  • 1褚道葆.电合成法制备纳米材料及纳米材料电极上的电催化合成[J].精细化工,2000,17(z1):10-12. 被引量:4
  • 2张琳,袁金锁,唐芳琼,江龙.溶胶-凝胶法制备含纳米憎水SiO_2颗粒葡萄糖酶电极[J].中国科学(B辑),1995,25(7):701-703. 被引量:11
  • 3徐鹏,王玉国,刘学武,孟庭宇,李志义.纳米TiO_2的制备、表面处理及表征的研究进展[J].现代涂料与涂装,2006,9(6):39-43. 被引量:8
  • 4[2]ZHANG Y,HE P L,HU N F,et al.Horseradish Peroxidase Immobilized in TiO2 Nanoparticle Films on Pyrolytic Graphite Electrodes:Direct Electrochemistry and Bioelectrocatalysis[J].Electrochimica Acta,2004,49:1981-1988.
  • 5[3]FAN Y,KAFI A K M,SHIN Hoon-Kyu,et al.A Novel Amperometric Hydrogen Peroxide Biosensor Based on Immobilization of Hemoglobin in Linoleic Acid Monolayer by Langmuir-Blodgett Technique[J].2006,15:284 -286.
  • 6[4]REN X L,MENG X W,TANG F Q,et al.Preparation of Ag-Au Nanoparticle and its Application to Glucose Biosensor[J].2005,110:358-363.
  • 7Silva, M. A.; Burrows, H. D.; Formosinho, S. J. Mater.Lett. 1991, 11(3), 96.
  • 8Lukachova, L. V.; Karyakin, A.; Ivanova, Y. N.;Karyakin, E. E.; Varfolomeyer, S. D. Analyst. 1998,123, 1981.
  • 9Li, J.-R.; Cai, M.; Chen, T.-F.; Jiang, L. Thin Solid Films 1989, 180, 205.
  • 10Crumbliss, A. L.; O' Daly, J. P.; Perine, S. C.;Stonehuemer, J.; Tubergen, K. R.; Zhao, J.; Henkens,R. W. Biotechnol. Bioeng. 1992, 40, 483.

共引文献52

同被引文献41

引证文献3

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部