摘要 针对农村电网谐波源的复杂特性,设计了基于LabVIEW技术的、开放式的农网谐波监测平台,该平台既可以通过高速数据采集卡获取实际电网或标准谐波源中的谐波信号,也可以加载基于LabView或Matlab仿真生成的任意组合的虚拟谐波信号。集成了FFT等多种信号处理方法,用于谐波信号的检测与分析。仿真算例表明,运用基于汉宁窗的FFT方法检测农网常见谐波,可以获得较理想的结果。 In consideration of the complex characteristic of harmonics sourees of rural power network one open harmonics monitoring platform was developed based on the LabVIEW technology. The platform could not only obtain the harmonic signals from actual power network or standard harmonic sources by using high speed data acquisition card, but also simulate to generate any random combined virtual harmonic signals by loading the Simulink of LabView or Matlab. There were many process methods in the platform for detection and analysis of the signals such as integration of FTT. The simulated calculation example indicated that the based on Hanning Window's FTT method could detect harmonics of rural power network with the best results.
出处 《沈阳农业大学学报》 CAS CSCD 北大核心 2007年第6期874-876,共3页 Journal of Shenyang Agricultural University
基金 沈阳农业大学青年硕士导师基金(200612)
关键词 谐波监测 LABVIEW 谐波信号 FFT harmonics monitoring LabVIEW harmonic signal FFT
  • 相关文献

参考文献4

二级参考文献20

  • 1袁浩,朱畅,陈志敏.基于LabVIEW的自动控制仿真系统设计[J].实验室研究与探索,2006,25(4):457-459. 被引量:9
  • 2[5]Lobo T,Leonowicz Z,Rezmer J,Koglin H-J.Advanced signal processing method of harmonics and interharmonics estimation.IEE 2001,Developments in Power System Protection,315~318
  • 3[6]Jain Vijay K,Collins Willim L.High-accuracy analog measurements via interpolated FFT.IEEE Trans.IM,1979,128∶113~122
  • 4[7]Grandke Tomas.Interpolation algorithms for discrete fourier transform of weighed signals.IEEE Trans.IM,1983,132∶350~355
  • 5[1]Mitra Sanjit K.Digital signal processing-a computer-based approach.McGraw Hill Companies inc,2001
  • 6[2]Chu R F and Burns J J.Impact of cycloconverter harmonics.IEEE Trans.IA,1989,123∶427~435
  • 7[3]Li Chun,Xu Wilson.On the ambiguity of defining and measuring inter-harmonic.IEEE Power Engineering Review,July 2001∶56~57
  • 8[4]Hack Don,Runtz Ken,Mason Ralph.An efficient algoritm for high resolution,power quality measurements of sparsely distributed power system harmonics and inter harmonics.IEEE WESCANX'95 Proceeding,24~29
  • 9DKarimi M, Mokhtari H, Iravani M R. Wavelet based on-line disturbance detection for power quality applications.IEEE Trans. on Power Delivery,2000.15 (4) : 1212-- 1220.
  • 10Yang H T, Liao C C. A de-noising scheme for enhancing wavelet-based power quality monitoring system. IEEE Trans. on Power Delivery, 2001, 16 (3): 353--359.

共引文献202

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部