摘要
针对山西省1000kV计量用电容式电压互感器的现场误差检测,给出了3种试验方法,并且相应做了设备的选型。对不同的试验方法进行了技术、经济比较,最后提出自己选择的试验方案。
According to on-the-spot error decection of 1 000 kV capacitor voltage transformer measuring in Shanxi province, three main test methods and device selection are proposed, after the technique and economic comparison of different testing methods, the final program is put forward.
出处
《山西电力》
2007年第B12期23-25,共3页
Shanxi Electric Power
关键词
电容式电压互感器
检测装置
特高压
capacitor voltage transformer
measuring device, untra-high voltage (UHV)