混凝土防渗墙厚度的确定是防渗墙设计的重要内容。通过对墙体材料、抗渗及耐久性能要求、防渗结构应力应变要求、地质条件、施工条件、环境水质以及类似工程经验等因素的分析,提出了防渗墙厚度的确定方法和步骤。
It is a main tark in designing anti-seepage wall to determine its thickness. By analysing Wall-buiding materials, reguire mento for anti-seepage and durability and for anti-seepage structures' stress and strain, geological conditions, fabricating conditions, environmental water guality and analogous fabricating experiences, the paper suggests the method and process to determine the thickness of anti-seepage wall.