摘要 国外多数抗震设计规范对各种类型结构建议了3档延性等级和地震力调节系数的可选择方案,并考虑了不同程度的超强,通过对我国9度区3跨6层钢筋混凝土框架结构进行的非线性动力反应分析,结果表明,赋予不同屈服水准的框架结构具有相近的超强水准。 Three ductility degrees and corresponding force modification factors for different structure types are suggested in foreign seismic codes, and take into account overstrength factor varied. Through inelastic dynamic response analysis of 3-hay & 6-story reinforced concrete frames systems which are endowed with different design seismic action in Earthquake Intensity Region 9, it is verified that those frames exist approximative overstrength level under separate earthquake action.
出处 《山西建筑》 2008年第4期100-101,共2页 Shanxi Architecture
关键词 延性等级 超强 地震力调节系数 非线性动力反应分析 框架结构 ductility degree, overstrength, force modification factor, nonlinear dynamic response analysis, frame construction
  • 相关文献

参考文献4

  • 1GB50011-2001.建筑抗震设计规范[S].[S].,..
  • 2IBC 2003.International Building Code[S].International Code Council.Inc.May,2003.
  • 3官伟,赖颖.框架结构地震反应的弹塑性时程分析[J].山西建筑,2006,32(9):43-44. 被引量:2
  • 4J.E.Martinez-Rueda.Scaling procedure for natural accelerograms based on a system of spectrum intensity scales[J].Earthquake Spectra,1998,14(1):135-152.

二级参考文献1

  • 1王松涛,曾资.现代抗震设计方法[M].北京:中国建筑工业出版社.2000.49-50.

共引文献2211