摘要
对直埋供热管道的应力及失效原因进行了分析,对管径相对较大的直埋供热管道的主要失效方式及原因进行了阐述,并探讨了大管径热网直埋供热管道设计中应注意的问题,对直埋供热管道的设计具有参考价值。
Based upon analysis of the stress and reasons caused the failures of direct-buried heat supply pipeline the major reasons caused the failure of direct-buried heat supply pipeline with larger diameters are elaborated. In addition, questions deserving attention in design of largediameter direct-buried heat supply pipeline are discussed, which has a certain reference value for similar works.
出处
《山西建筑》
2008年第4期200-201,共2页
Shanxi Architecture
关键词
供热管道
失效方式
局部失稳