摘要 以岭澳核电站为分析对象,利用MELCOR和TONUS(CEA)程序进行分析计算,给出了初步的消氢系统设计方案,对不同核电站的消氢系统设计方案进行了对比和讨论。结果表明:安全壳内安装33个FR750型或者17个左右的FR1500型氢气复合器可以满足氢气控制要求。 In severe accident of PWR, large amount of hydrogen may accumulate in the containment, combustion or detonation may occur and challenge the integrity of containment. Passive autocatalystic recombiners (PARs) should be installed to mitigate the hydrogen risk. Aiming at Lingao phase 2 nuclear power plant, using MELCOR and TONUS, a preliminary design of hydrogen mitigation system has been given. Different hydrogen mitigation systems are also compared in this paper.
出处 《核动力工程》 EI CAS CSCD 北大核心 2008年第1期30-34,共5页 Nuclear Power Engineering
关键词 大型干式安全壳 非能动催化氢气复合器 严重事故 自燃反应 Large dry containment, Passive autocatalystic recombiners, Severe accident, Spontaneous hydrogen combustion
  • 相关文献

参考文献4

  • 1Bonic G, Dabbene F. TONUS 0 D Version 2005.1- Physical Models[R]. SFME/LTMF/RT/05-038/A, 2005.
  • 2岭东核电有限公司.岭澳二期核电站PSA总报告[R].岭东核电有限公司,2005.
  • 3Turtiainen A. Verification of SIEMENS FR Recombiner Model Implemented in TONUS 0 D Code[R]. SFME/ LTMF/RT/04-032/A, 2004.
  • 4Molchanov A, Rubinshtein M. TIANWAN ANP System Design File Containment Hydrogen Removal System (JMT) [R]. LYG1PD86810JMT0000EN0001E, 2003.