摘要
通过实证来分析充气中空玻璃所面临的更基本的、但更具有实践指导意义的一些基本问题,比如充气浓度90%(或95%)与100%的中空玻璃的传热系数的对比,何时使用惰性气体使中空玻璃达到更大更经济的节能效果,惰性气体的泄漏原因及提高中空玻璃惰性气体的保持能力的根本方法,充气中空玻璃适应的范围,等等。
Some fundamental and guidance to practice issues which gas filled insulating glass faces were analyzed ,such as comparison of heat transfer coefficient between insulating glass units (IGU)in which gas concentration is 90%(or 95%) and 100%. It is pointed out that how to use inert gas for getting better energy saving effect in tGU , the causes of leakage of inert gas and the measures to keep inert gas in IGU tight as well as the scope of gas filled IGU.
出处
《玻璃》
2008年第1期41-45,共5页
Glass
关键词
惰性气体
片压强
初始浓度
年泄漏率
非破坏性检测仪器
inert gas , intensity of pressure, initial concentration, leakage rate per year, intact detecting instrument