期刊文献+

超声造影在移植肾急性排斥反应的初步临床研究 被引量:15

Contrast-enhanced sonography in the diagnois of acute rejection of transplanted kidney
下载PDF
导出
摘要 目的探讨经静脉声学造影对移植肾急性排斥反应的诊断价值。方法对18例肾移植患者进行移植肾超声造影,测量并计算峰值密度(PI)、曲线下面积(AUC)等参数,按病理和临床诊断结果将其分为正常、轻度急性排斥反应和中重度急性排斥反应3组进行对比研究。结果PI值比较,正常组(9例)与轻度急性排斥反应组(4例)之间无显著差异,正常组与中重度急性排斥反应组(5例)之间有显著差异;而AUC值,轻度和中重度急性排斥反应组与正常组之间均有显著差异。将轻度急性排斥反应组和中重度急性排斥反应组合为一组与正常组比较,则PI无显著差异,而AUC仍有显著差异。结论移植肾超声造影的血流灌注参数AUC与肾血流量密切相关,是较客观、准确的观测指标,为临床诊断移植肾急性排斥反应提供了新的方法。 Objective To investigate the value of contrast- enhanced sonography in the diagnosis of acute rejection of transplanted kidney. Methods Eighteen patients with transplanted kidneys were divided into three groups: normal group, mild- rejection group and moderate to severe - rejection group according to the parameters such as PI, AUC which were gathered and calculated after contrast- enhanced sonography. Results Nine patients were in normal group, 4 in mild- rejection group and 5 in moderate to severe - rejection group, respectively. PI had no significant difference between normal and mild- rejection group, while significant difference between normal and moderate to severe- rejection group. Meanwhile, differences of AUC value among the three groups were significant. The PI value had no significant difference between normal group and rejection group, while AUC value had significant difference. Conclusion AUC derived from contrast - enhanced sonography has close correlation with renal blood flow. As a objective and accurate index, it could provide a new method for clinical diagnosis of acute rejection in transplanted kidney.
出处 《临床超声医学杂志》 2008年第1期7-9,共3页 Journal of Clinical Ultrasound in Medicine
关键词 超声检查 造影剂 肾移植 急性排斥反应 诊断价值 Uhrasonography,contrast agent Kidney transplantion Acute rejection
  • 相关文献

参考文献9

二级参考文献29

  • 1Forsberg F,Ultrasonics,1998年,36卷,1-5期,695页
  • 2Wei K,J Am Coll Cardiol,1997年,29卷,1081页
  • 3张武,现代超声诊断手册,1996年
  • 4Tiefenthaler M,Riedl-Huter C. Value of sonography in kidney transplantation. Acta Med Austriaca,2001,28:74-77.
  • 5Claudon M,Lefevre F,Hestin D,et al. Power Doppler imaging: evaluation of vascular complications after renal transplantation. Am J Roentgenol,1999,173:41-46.
  • 6Bouakaz A,Frigstad S,Ten Cate FJ,et al. Improved contrast to tissue ratio at higher harmonics. Ultrasonics,2002,40:575-578.
  • 7Claudon M,Barnewolt CE,Taylor GA,et al. Renal blood flow in pigs: changes depicted with contrast-enhanced harmonic US imaging during acute urinary obstruction. Radiology,1999,212:725-731.
  • 8Georage AT,Carol EB,Brent H,et al. Renal cortical ischemia in rabbits revealed by contrast-enhanced power Doppler sonography. Am J Roentgenol,1998,170:417-422.
  • 9Lefevre F,Correas JM,Briancon S,et al. Contrast-enhanced sonography of the renal transplant using triggered pulse-inversion imaging: preliminary results. Ultrasound Med Biol,2002,28:303-314.
  • 10Gaschen L,Schuurman HJ. Ultrasound score is more predictive than serum creatinine in assessment of cellular rejection in cynomolgus monkey renal allografts. Invest Radiol,2002,37:376-380.