摘要
压力容器用钢板1.25Cr0.5MoSi-20℃夏比(V型缺口)冲击吸收功复验值不合格,经对钢板热处理状态的分析,改变钢板热处理状态,重新进行-20℃夏比(V型缺口)冲击试验,试验结果合格。
The Charpy V-notch impact test value of 1.25Cr0.5MoSi steel plate for pressure vessels at --20℃ is unqualified in the rechecking before acceptance,after analyzing the reason and modified the steel’s heat-treatment state, the Charpy V-notch impact test value is qualified at -- 20℃.
出处
《石油化工设备》
CAS
2008年第1期61-63,共3页
Petro-Chemical Equipment