摘要
根据现场施工的实践经验,分析了光缆接续工艺密封性能不良的原因,针对这些原因,提出了相应的改进措施,并结合实际的施工经验阐述了现场施工中在进行光缆接续时防止密封性能不良的具体操作要点。
According to the practice experience of field construction, it analyses the reasons of the pooxr sealing function of cable jointed technology, and puts forward the corresponding improving steps according to these reasons. And combined with the practical field construction, it represents the specific operating points of preventing the poor sealing function in jointing the cable in field construction.
出处
《山西建筑》
2008年第5期220-221,共2页
Shanxi Architecture
关键词
光缆
接续工艺
密封性能
cable, jointed technology, sealing function