摘要
茂名石化分公司动力厂2台410t/h循环流化床锅炉投运后,锅炉原煤仓经常发生堵煤现象。通过调研和分析,对锅炉原煤仓结构进行改造,改造取得了预期的效果,较好地解决了循环流化床锅炉煤仓堵煤的问题。
After the two 410t/h circulating fluidized bed(CFB) boilers in the power plant of SINOPEC Maoming branch put into running,coal blocking often occurred in the coal silo of boiler.After measuring and analyzing,the silo structure was rebuilt,with this the problem of coal blocking in coal silo of CFB boiler was solved.
出处
《机电工程技术》
2007年第12期101-102,118,共3页
Mechanical & Electrical Engineering Technology
关键词
循环流化床锅炉
原煤仓
堵煤
改造
circulating fluidized bed boiler
coal silo
coal blocking
rebuild