摘要
介绍了XGI.P型脉动真空灭菌器各程序蒸汽流程的工作原理,并对灭菌时段经常出现升温慢,消毒后包裹不够干燥,在运行过程中安全阀经常喷气或压力升得慢等故障进行了分析与排除。
Describes the working principles of all flow processes of T XGI.P pulsation vacuum sterilizer. Analyzes the malfunctions of frequently slow temperature rising in the time of sterilization, insufficient drying of packages after sterilization and often jetting of release valve and slow pressure rising in the operation, etc. and puts forward the solutions of troubleshooting,
出处
《医疗设备信息》
2007年第12期94-95,共2页
Information of Medical Equipment
关键词
脉动真空灭菌器
灭菌设备维修
pulsation vacuum sterilizer