摘要
对电容器投切产生的动态电压波动情况进行了分析评价。以电能质量分析理论为基础,选择两个典型的变电站进行实测,从电容器投切产生的供电母线动态电能质量指标特征和电压瞬态特征进行了评价。
The voltage fluctuation on the bus due to capacitor switching is analyzed. Based on the power quality theory and the measured data of two typical substations, the dynamic power quality indices for the bus during switching of the capacitor are evaluated, as well as the transient characteristics of the voltage.
出处
《华东电力》
北大核心
2007年第12期53-56,共4页
East China Electric Power
关键词
电能质量
城市配电网
电容器
投切
电压波动
power quality
city distribution network
capacitor
switching
voltage fluctuation