摘要 目的探讨临床上使用的口腔体温计的检测周期。方法选择4个不同产地的合格的口腔体温计各100支,在使用2周、4周、6周、8周、10周、12周后进行体温计的准确性检测。结果400支检测的体温计在使用2周、4周、6周、8周、10周、12周后,合格率分别是94.8%、90.7%、87.1%、80.7%、69.0%、52.7%,显示准确性逐渐下降。结论应该加强对使用中体温计准确性的检测,建议每2周检测1次。 Objective To explore the testing period for orally-used thermometer. Methods 400 orally-used qualified thermometers from 4 production places, every 100 from each place, were tested for the accuracy at week 2, week 4, week 6, week 8, week 10 and week 12. Results The checkout rates for all the 400 thermometers were 94.8%, 90.7%, 87.1%, 80.7%, 69.0% and 52.7% at week 2, week 4, week 6, week 8, week 10 and week 12, indicating the accuracy was falling. Conclusion The testing of thermometers at use should be intensified. It is suggested to test them once every two weeks.
机构地区 丽水市中心医院
出处 《护理学报》 2008年第1期70-71,共2页 Journal of Nursing(China)
关键词 口腔体温计 检测周期 合格率 orally-used thermometer testing period checkout rate
  • 相关文献

参考文献5

二级参考文献7

  • 1余爱珍.基础护理学[M].南京:江苏科技出版社,1993.75.
  • 2[1]NBS.SP260-87.1983年
  • 3[2]Temperature fixed points: Evaluation offour types of triple point cell J.D.Cox and M.F. Vaughan.
  • 4[3]NPL Report Chem 86 1978。
  • 5余爱珍.护理学基础[M].南京:江苏科学技术出版社,1995.75.
  • 6季可,杨全喜,田生亮,郑凤华,贾瑞华.一种新型的体温计校准装置[J].计量技术,2000(6):25-28. 被引量:2
  • 7梁月香,钱国珍.体温表检测方法及其比较[J].护士进修杂志,2000,15(9):710-711. 被引量:4