期刊文献+

牙齿表面不同状态对自酸蚀体系剪切强度影响的实验研究 被引量:3

Evaluate of shear bonding strength of a self-etching.adhesive to enamel and dentine in different conditions
下载PDF
导出
摘要 目的:研究牙釉质、牙本质表面不同状态对自酸蚀体系剪切强度的影响。方法:选择新鲜拔除无龋坏、无缺损的牛切牙,低速金刚砂片切取厚约2.0mm,面积大小3.5~4.0mm的牙釉质、牙本质片各32个,依次以200目、400目、600目砂纸打磨,按如下处理:①在湿润条件(人工唾液)下;②在半干燥(棉球沾干表面)下;③干燥条件(气枪吹干)下,采用自酸蚀粘结系统固定内径为4mm、高为2mm的铜环。加压充填树脂,分层固化,同时以全酸蚀粘结系统作对照组。所得的试件分别分为4组:即刻测试组(自酸蚀和全酸蚀)和24h后测试组(自酸蚀和全酸蚀),每组8试件。即刻测试:将粘结处理完成后的试件直接放置在万能试验机上测试其剪切强度,剪切头速度为0.5mm/min。24h后测试:将粘结处理完成后的试件放置在人工唾液中24h,在万能试验机上测试其剪切强度,剪切头速度为0.5mm/min。结果:经统计分析,可知3种不同状态在自酸蚀粘结系统下即刻和24h测试组比较组内及组间均存在显著差异(P<0.01),与对照组比较,自酸蚀即刻测试组存在显著差异(P<0.01),自酸蚀24h测试组的剪切强度值存在显著差异(P<0.01)。结论:①牙釉质、牙本质表面在半干燥条件下的即刻和24h测试组的剪切强度值最大,与其他两组存在显著差异(P<0.01);②3种条件下的24h测试组的剪切强度值较即刻测试组的剪切强度值大,存在显著差异(P<0.01);③与全酸蚀为对照组的比较,即刻组的剪切强度值均小于对照组的剪切强度值,存在显著差异(P<0.01),24h测试组的剪切强度值大于对照组的剪切强度值,存在显著差异(P<0.01)。 Objective The aim of this study was to compare immediate and 24-hour of shear bond strength (SBS) of self-etching systems on difference conditions. Methods 32 freshly extracted bovine flat enamel and,dentine surfaces, were produced by wet grinding on a 200,400,600,800-grit SiC paper, and mounted in acrylic. The flat enamel surfaces were treated by three conditions: overdrying, overwetting and middlewetting.The samples were clamped in a stand under a split copper mould with a hole in the centre (4 mm diameter,2 mm high).The mould was then filled in increment with a composite resin (Z100) The adhesive was applied in accordance with the manufacturer's instructions. Specimens for immediate bond strength testing were placed in a test machine according to the previously reported method within 1 minute of light-initiation.Specimens for 24-hour bond strength testing were stored in distilled water until testing.The crosshead speed was 0.5mm/min. Total etch system group as control Results were analyzed using one way ANOVA. Results There were significant differences between immediate and 24-hour groups (P〈0.01) there were also significant differences compare with control group(P〈0.01). Conclusion The flat enamel surfaces treated in middlewetting were significant differences compare to others conditions. There were also significant differences between immediate and 24- hour groups.
出处 《中国美容医学》 CAS 2008年第1期92-94,共3页 Chinese Journal of Aesthetic Medicine
关键词 剪切强度 自酸蚀体系 牙釉质 shear bonding strength enamel dentine self-etching adhesive
  • 相关文献

参考文献17

  • 1Fusayama T,Nakamura M,Kurosaki N,et al.Non-pressure adhesion of a new adhesive restorative resin[J].J Dent Res, 1979,58:1364-1370.
  • 2Chigira H,Koike T,Hasegawa T,et al.Effect of the self-etching dentin primers on the bonding efficacy of a dentin adhesive[J].Dent Mater J, 1989,8(1):86-92.
  • 3陈吉华.现代口腔粘结技术的临床应用概况[J].中国口腔修复学通讯,2000,3:46-47.
  • 4Perdigo J,Lopes M.Dentin Bonding-Question for the new millennium [J].J Adhesive Dent, 1999,1:191-209.
  • 5Hasegawa T, Manabe A, Itoh K, et al. Investigation of self-etching dentin primers[J].Dent Mater, 1989,5: 408-410.
  • 6Watanabe I, Nakabayashi N, Pahley DH. Bonding to ground dentin by a Phenyl-P self-etching primer[J].J Dent Res, 1994,73: 1212-1220.
  • 7Krejci I, Hausler T, Sagesser, et al. New adhesives in Class Ⅴ restorations trader combined load and simulated dentinal fluid [J]. Dent Mater,1994,10(5): 331-335.
  • 8Inagaki A, Chigira H, Itoh K, et al. Effects of self-etching primers on dentin[J].Dent Mater, 1989,5(6): 403-407.
  • 9Perdigo J, Lopes L, Lambrechts P, et al. Effects of a self-etching primer on enamel shear bond strengths and SEM morphology[J].Am J Dent, 1997,10: 141-146.
  • 10Pereira PNR, Okuda M, Sano H, et al. Effect of intrinsic wetness and regional difference on dentin bond strength [J].Dent Mater, 1999,15: 46-53.

共引文献3

同被引文献33

  • 1谭建国,周丽晶,冯海兰.3种酸蚀方法处理硬化牙本质表面的超微形态研究[J].口腔医学,2005,25(3):143-145. 被引量:15
  • 2贾霄云.瓷修复中树脂粘接剂的应用配合[J].护士进修杂志,2005,20(11):1050-1051. 被引量:6
  • 3Jalalian E, Aletaha NS. The effect of two marginal designs (chamfer and shoulder) on the fracture resistance of all ce- ramic restorations, Inceram: An in vitro study [J]. Prosth- odont Res, 2011, 55(2) : 121-125.
  • 4Vult von Steyern P, A1-Ansari A, White K, et al. Fracture strength of In-Ceram all-ceramic bridges in relation to cer- vical shape and try- in procedure. An in- vitro study [J]. Eur J prosthodont Restor Dent, 2000, 8(4) : 153-158.
  • 5Kokubo Y, Nagayama Y, Tsumita M, et al. Clinical margin- al and internal gaps of In-Ceram crowns fabricated using the GN-I system [J]. J Oral Rehabil, 2005, 32(10) : 753- 758.
  • 6Nakamura T, Dei N, Kojima T, et al. Marginal and internal fit of CEREC3 CAD/CAM all- ceramic crowns [J]. Int J prosthodont, 2003, 16(3) : 244-248.
  • 7Chan DC, Wilson AH, Barbe P, et al. Effect of preparation convergence on retention and seating discrepancy of complete veneer crowns [J]. J OralRehabiI, 2004, 31(10) : 1007- 1013.
  • 8Uo M, Sjogren G, Sundh A, et al. Cytotoxicity and bondingproperty of dental ceramics [J]. Dent Mater, 2003, 19(6) : 487- 492.
  • 9Schulze KA, MarshalI SJ, Gansky SA, et al. Color stability and hardness in dental composites after accelerated aging [J]. Dent Mater, 2003, 19(7) : 612-619.
  • 10Liu B, Lu C, Wu Y, et ai. The effects of adhesive type andthickness on stress distribution in molars restored with all -ceramic crowns [J]. J Prosthodont, 2011, 20(1) : 35-44.

引证文献3