期刊文献+

煤矿井下杂散电流的防治

Prevention and Dealing of Distributed Current in Coal Mine
原文传递
导出
摘要 在煤矿井下直流架线电机车轨道的运输系统中,在轨道之外无规律性流动的电流称为杂散电流。通过减少钢轨的阻抗,增大通过钢轨的电流;铺设扁钢与钢轨连接,替代钢轨回流;缩短供电半径等方法来减少杂散电流。通过用作电流回路的轨道与不作电流回路的轨道之间加以绝缘、架线的吊线器及拉线绝缘子保持清洁等方法防止杂散电流。 In the underground colliery haulage system of aerial-cable DC driving train, the part of current which flows irregularly beyond the railway is defined as Stray Current. Usually, we can decrease the stray current by limiting the resistance of the steel railway, increasing the current flown through the railway, laying the flat steel that connect to the steel railway to conduct the return current, abridging the radius of power supply. Also, we can avoid the stray current by insulating the parts of the railways which conduct the return current from the parts which do not conduct the return current, and keeping clean of the apparatuses which are used to hung the wires and insulation units.
出处 《矿山机械》 北大核心 2008年第1期40-41,共2页 Mining & Processing Equipment
关键词 煤矿 杂散电流 防治 Colliery Stray current Prevention and dealing
  • 相关文献

参考文献5

  • 1辛广龙.《煤矿安全规程》问答[M].北京:煤炭工业出版社.2004.
  • 2中国作家协会天津分会编译所.煤矿安全知识讲座[M].1991.
  • 3李景恩.矿山供电[M].徐州:中国矿业大学出版社,1989.
  • 4国家煤矿安全监察局人事培训司.煤矿电气安全[M].徐州:中国矿业大学出版社,2002.
  • 5劳动人事部培训就业局.电工学[M].北京:劳动人民出版社,1989.