期刊文献+

A/O^2—MBR组合工艺处理冷轧含油废水 被引量:4

A/O^2 and MBR treatment of oil-contained wastewater from steel cold-rolling mill
下载PDF
导出
摘要 采用A/O^2—MBR组合处理冷轧含油废水,并应用固定化微生物技术克服了常规膜处理中"油封"对膜表面造成的污染,获得了一个长效、稳定的膜通量和高效的处理成果,出水COD_(Cr)<70 mg/L,出水水质可达《污水综合排放标准》(GB 8978—1996)一级标准。 Combined process of A/O^2 and MBR was applied to treat oil-contained wastewater from steel cold-rolling mill. Fixed microorganism was used to eliminate the pollution on the surface of the membrane caused by so-called oil seal. So long term and stably membrane flux and high effective treatment were obtained. The CODMn was less than 70 mg/L in effluent, which was quite enough to meet the requirement of class I of the national Integrated Wastewater Discharge Standard (GB 8978-1996).
出处 《给水排水》 CSCD 北大核心 2007年第11期64-66,共3页 Water & Wastewater Engineering
关键词 冷轧含油废水 MBR 固定化微生物 油封 Oil contained wastewater from steel cold- rolling MBR Fixed microorganism Oil seal