期刊文献+

值得关注的生物安全实验室消防解决方案 被引量:2

A fire solution of concerned biosafety laboratory
下载PDF
导出
摘要 说明了以生物安全为核心的生物实验室的消防设计特点,在建筑、给排水、暖通和电气各专业的细节设计上体现出在生物安全前提下,确保实验室人员的安全撤离;对灭火设备的需求是能有效控制火灾,将二次污染、灭菌设备和消防设备造价降至最低;在防烟排烟以及火灾探测和报警等方面都提出了几种解决方案。在国内尚无工程实例的情况下,是对这一崭新领域的尝试和探索。 Biology laboratory's fire design features with the core of the biological safety is described. Under the premise of biosafety which is reflected on professional details ,such as the construction, drainage, electrical and HVAC, that laboratory personnel can safely evacuate is ensured. The demand for the fire fighting equipment is effective in controlling the fire, depreciating the cost of secondary pollution, sterilization equipment and firefighting equipment to minimum. Several solutions are proposed in the aspects of exhaust smoke, fire detection and alarm. As there is no engineering examples in China,it is an attempt and exploration in this new area.
作者 晁海鸥
出处 《消防科学与技术》 CAS 2008年第1期25-27,共3页 Fire Science and Technology
关键词 生物安全 三级 四级实验室 病源微生物外泄 二次污染 消防安全 Biosafety the third and Fourth level laboratories Fathogenic microorganisms leakage Second pollution Fire features
  • 相关文献

参考文献5

  • 1GB50346—2004,生物安全实验室建筑设计规范[S].
  • 2GB19489—2004.实验室生物安全通用要求[S].[S].,..
  • 3李劲松.病源微生物实验室的生物危害和生物防护[C].中国实验动物学会第七届学术年会论文集,2006.
  • 4曲连东.三级动物实验生物安全实验室的工艺设计探讨[C].中国实验动物学会第七届学术年会论文集,2006.
  • 5徐火炬.科学建设符合世界先进生物安全标准的高度隔离生物安全实验室[C].中美生物安全实验室研讨会,2007.