摘要
目的调查天津地区UF-50尿沉渣分析仪的正常参考值。方法用尿常规分析仪和尿液离心镜检两种方法筛选出正常尿液标本704份,用UF-50尿沉渣分析仪测定白细胞、红细胞、上皮细胞、管型、细菌的值,用百分位数法确定参考值。结果在95%可信区间的UF-50尿沉渣分析仪的参考范围为:红细胞0~14.8个/微升,白细胞0~17.3个/微升,上皮细胞0~14.7个/微升,管型0~0.44个/微升,细菌0~2642.3个/微升。结论确定的参考范围基本可信,应用UF-50进行尿沉渣检查结果可靠,可广泛应用于临床泌尿系统疾病的辅助诊断。
Objective To investigate the reference ranges of multiple indices with UF-50 urine sediment analyzer in Tianjin Region. Methods Urinary routine analyzer assay and urinary sediment microscopic analysis were performed to screen 704 normal urine samples. UF-50 urinary sediment analyzer was adopted to determine reference ranges of multiple indices [red blood cells (RBC), white blood cells (WBC) , epithelial cells (EC), casts and bacteria] with percentile method. Results The multiple indices reference ranges of 95% confidence interval with UF-50 urine sediment analyzer were as follows : RBC 0-14.8,WBC 0-17.3,EC 0-14. 7,casts 0-0.44,and bacteria 0-2 642.3. Conclusion The established reference ranges are credible. UF-50 urine sediment analyzer can acquire experimental results reasonable, and can be widely used in the clinical diagnosis of disorders of urinary system.
出处
《检验医学与临床》
CAS
2008年第3期136-137,共2页
Laboratory Medicine and Clinic
关键词
UF-50尿沉渣分析仪
白细胞
参考值
UF-50 urine sediments analyzer
white blood cells
reference ranges