期刊文献+

百叶窗式喷射塔板的性能研究 被引量:2

Study on performance of louver jet tray
下载PDF
导出
摘要 为满足炼油化工装置扩能改造的要求,文中提出了一种百叶窗式喷射塔板。采用空气-富氧水体系,在φ1200 mm不锈钢塔内,对百叶窗式喷射塔板的流体力学与传质性能进行了测试,回归了压降、泄漏、雾沫夹带等计算关联式,并与新垂直筛板进行了对比实验。结果表明,与新垂直筛板相比,百叶窗式喷射塔板的压降减少16%左右,泄漏率基本相当,雾沫夹带率降低20%左右,传质效率提高3%—10%。实验结果与工业应用实践证实,百叶窗式喷射塔板是一种综合性能优异的塔板。 In order to satisfy the revamping of refinery and chemical equipments, a new kind of tray, louver jet tray (LJT) , was presented. The hydraulic and mass transfer performances of LJT and new vertical sieve tray ( New VST) were investigated with air-water-oxygen system in a stainless steel column of φ 1 200 mm. Equations of hydraulic parameters such as pressure drop, weeping and entrainment were regressed. The experimental results show that compared with New VST, LJT has pressure drop lowered by 16% , entrainment lowered by 20% and efficiency increased by 3% -10% and the same weeping rate. Both test results and industrial application experience indicate that LJT has super performance.
出处 《化学工程》 EI CAS CSCD 北大核心 2008年第1期13-16,共4页 Chemical Engineering(China)
关键词 百叶窗式喷射塔板 压降 泄漏 雾沫夹带 效率 louver jet tray pressure drop weeping entrainment efficiency
  • 相关文献

参考文献7

二级参考文献44

共引文献71

同被引文献24

引证文献2

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部