采用237季铵萃淋树脂和萃取色谱分离技术,在6.5mol/LHNO3介质中定量分离陶瓷UO2芯块粉末标准物质中铀与待测杂质元素。用ICP直读光谱仪同时测定流出液中Al、Ba、Co、Ta、Ti和V。分析结果均在标准值的置信区间内,相对标准偏差sr<7.5%。取样300mg时,测定下限为(0.016—0.250)×10-6。
The 237 quaternary ammonium extraction resin chromatography is used to separation 6 trace elements in ceramic uranium dioxide pellets powders,which are used as certified reference materials (CRMs).The sample is dissolved in 6 5 mol/L HNO 3 and uranium is separated by chromatographic column.The 6 trace elements Al,Ba ,Co,Ta,Ti and V contained in the elutriant are determined using ICP directly reading spectrometer.For a 300 mg sample,the lowest determinable concentration of impurities in ceramic UO 2 pellets powders CRMs is (0 016—0 250)×10 -6 .The relative standard deviation is less than 7 5%.The proposed method provides excellent and accurate analytical data for the ceramic UO 2 pellets powders samples (CRMs).