期刊文献+

适配子筛选技术 被引量:15

Methodology for Aptamer Selection
下载PDF
导出
摘要 适配子的筛选技术近年来不断改良与发展。结合核酸与游离核酸的分离技术的改良,使适配子筛选效率得到提高;无引物结合部位适配子的筛选技术的建立和短寡核苷酸文库的应用,使适配子的应用范围更加广泛;适配子筛选技术在功能上的拓展,满足了更多的研究要求。一系列新方法的建立和应用,使适配子在基础研究和临床应用方面更具潜在价值。 The methods for aptamer selection have efficiency has been increased due to the improvement been modified and developed in recent years. Selection in separation of bound and unbound nucleic acids; applicability of aptamers has been improved due to the development of primer-free SELEX and the utilization of short oligonucleotide library; more research requirements have been satisfied due to the functional modifications of aptamer selection methods. All the methodological advances enhance the potential value of aptamers in basic researches and clinical applications.
出处 《中国生物工程杂志》 CAS CSCD 北大核心 2008年第1期113-118,共6页 China Biotechnology
基金 国家"863"计划(2007AA02Z462) 江西省科技攻关项目(20061B0302400) 江西省教育厅科技项目(2006061) 资助项目
关键词 适配子 SELEX技术 Apatmer SELEX
  • 相关文献

参考文献31

  • 1Murphy M B, Fuller S T, Richardson P M, et al. An improved method for the in vitro evolution of aptamers and applications in protein detection and purification. Nucleic Acids Res, 2003, 31(18) :e110
  • 2Stoltenburg R, Reinemann C, Strehlitz B. FluMag-SELEX as an advantageous method for DNA aptamer selection. Anal Bioanal Chem, 2005, 383 ( 1 ) :83 - 91
  • 3Mendonsa S D, Bowser M T. In vitro selection of high-affinity DNA ligands for human IgE using capillary electrophoresis. Anal Chem, 2004, 76(18) :5387-5392
  • 4Tang J, Xie J, Shao N, et al. The DNA aptamers that specifically recognize ricin toxin are selected by two in vitro selection methods. Electrophoresis, 2006, 27 ( 7 ) : 1303 - 1311
  • 5Mosing R K, Mendonsa S D, Bowser M T. Capillary electrophoresis-SELEX selection of aptamers with affinity for HIV-1 reverse transcriptase. Anal Chem, 2005, 77 (19) :6107-6712
  • 6Mendonsa S D, Bowser M T. In vitro selection of aptamers with affinity for neuropeptide Y using capillary electrophoresis. J Am Chem Soc, 2005, 127(26) :9382-9383
  • 7Krylov S N, Berezovski M. Non-equilibrium capillary electrophoresis of equilibrium mixtures- appreciation of kinetics in capillary electrophoresis. Analyst, 2003, 128 (6) :571-575
  • 8Berezovski M, Drabovieh A, Krylova S M, et al. Nonequilibrium capillary eleetrophoresis of equilibrium mixtures: a universal tool for development of aptamers. J Am Chem Soc, 2005, 127(9) :3165-3171
  • 9Cox J C, Ellington A D. Automated selection of anti-protein aptamers. Bioorg Med Chem, 2001, 9(10) :2525 -2531
  • 10Eulbcrg D, Buchner K, Maasch C, et al. Development of an automated in vitro selection protocol to obtain RNA-based aptamers: identification of a biostable substance P antagonist. Nucleic Acids Res, 2005, 33(4) :e45

同被引文献362

引证文献15

二级引证文献47

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部