摘要 采用荧光偏振免疫法(FPIA)测定肾移植受者环孢素A(CsA)全血谷浓度,结果发现食物、性别、肝脏功能等均是影响CsA全血谷浓度的重要因素;从免疫抑制效果看,术后3个月、3~6个月、6个月以上的理想稳态血浓范围分别为200~380ng·ml-1、150~330ng·ml-1和100~250ng·ml-1。 Cyclosporine A has greatly improved graft survival in kidney transplants.The trough concentration of CsA in whole blood was determined by FPIA.The results showed that food,sex,liver function were important factors influencing the trough concentration.It was found that under 3 months 3 ̄6months and more than 6 months after operation,the expected steady state range of blood concentration was 200 ̄380ng\5ml -1 ,150 ̄330ng\5ml -1 and 100 ̄250ng\5ml -1 respectively.
出处 《中国医院药学杂志》 CAS CSCD 北大核心 1997年第6期245-246,共2页 Chinese Journal of Hospital Pharmacy
关键词 环孢素A 荧光偏振免疫法 血药浓度 免疫抑制剂 cyclosporine A,flouresence polarization immunoassay,whole blood trough concentration