期刊文献+

真皮与血管漫反射光谱的相关性研究

Correlation analysis of skin spectra and blood vessel spectra
下载PDF
导出
摘要 基于真皮与血管漫反射光谱的相关性活体实验研究真皮漫反射光谱法测量血糖浓度的可行性:成功剥离兔子股动脉血管,实现血管光谱的直接测量;在调节兔子的血糖浓度变化的过程中,同时监测兔子的血管漫反射光谱和皮肤漫反射光谱。实验结果表明,血管漫反射光谱与皮肤漫反射光谱之间的相关系数达到0.88以上。分别基于血管漫反射光谱和皮肤漫反射光谱建立校正集模型,并预测得到相应的血糖浓度集G1和G2,两组血糖浓度预测值之间的相关系数为0.90。因此,真皮漫反射光谱信号能够有效地反应血液信息,从而实现血糖浓度的无创检测。 The feasibility of noninvasive blood glucose sensing with near-infrared spectra from the dermis layer was studied. By in-vivo rabbit experiment, the diffuse reflectance spectra from dermis and blood vessel were collected simultaneously at different blood glucose levels. The result shows that the correlation coefficient between the two spectra matrix is higher than 0. 88. Then two sets of blood glucose concentrations were predicted by calibration models based on the spectra from dermis and blood vessel respectively. The correlation coefficient between the former and the latter set is 0. 90. Therefore, the spectra signal from dermis can effectively represent the information of blood glucose.
出处 《现代仪器》 2008年第1期39-41,共3页 Modern Instruments
基金 十一五国家科技支撑计划重大项目(No.2006BAI03A03) 国家自然科学基金(No.30600126) 中国博士后科学基金(No.20060390661)
关键词 相关性 血糖 真皮光谱 血管光谱 Correlation Blood glucose Dermal spectra Vascular spectra
  • 相关文献

参考文献9

  • 1[1]Maruo K,Oota T,Tsurugi M,et al..New methodology to obtain a calibration model for noninvasive near-infrared blood glucose monitoring,Appl.Spectros.,2006,60:441 ~449
  • 2[2]Arnold M A,Small G W.Noninvasive glucose sensing,Anal.Chem,,2005,7:5429 ~ 5439
  • 3[3]Khalil O S.Non-invasive glucose measurement technologies:an update from 1999 to the dawn of the new millennium,Diabetes Technol.Ther.,2004,6:660~697
  • 4[5]Thennadil S N,Rennert J L,Wenzel B J,et al..Comparison of glucose concentration in interstitial fluid,and capillary and venous blood during rapid changes in blood glucose levels,Diabetes Technol.Ther.,2001,3:357 ~ 365
  • 5[6]Barton F E,Himmelsbach D S,Duckworth J H,et al..Two-dimensional vibration spectroscopy:Correlation of midand near-infrared regions.Appl.Spectrosc.,1992,46:420 ~ 429
  • 6[7]Barton F E,Himmelsbach D S.Two-dimensional vibration spectroscopy Ⅱ:Correlation of the absorptions of lignins in the mid-and near-infrared.Appl.Spectrosc.,1993,47:1920 ~ 1925
  • 7[8]Xu Kexin,Qiu Qingjun,Jiang Jingying,et al..Non-invasive glucose sensing with near-infrared spectroscopy enhanced by optical measurement conditions reproduction technique.Optics and Lasers in Engineering,2005,13:1096 ~1106
  • 8[9]Frank I,Friedman J.A statistical view of some chemometrios regression tools,Technometrics,1993,35:109 ~ 135
  • 9[10]Lorber A,Kowalski B R.Alternatives to cross-validatory estimation of the number of factors in multivariate calibration,Appl.Spectro.,1990,44:1464 ~ 1470