南水北调中线惠南庄泵站进水前池布置方案的分析研究 被引量:7

Analyses of the Layout the Forebay of Hui-Nan-Zhuang Pump Station
下载PDF
导出
摘要 对于惠南庄泵站这样一座重要的大型城市供水泵站,为了满足其流量大、扬程高、单机容量大、泵站特征参数变幅大等特殊要求,在进水前池的设计中采用前池数值水力仿真分析、水工模型实验及三维紊流数值模拟等试验研究手段弥补现行规范中的一些空白,合理有效地控制前池内部流态对水泵吸水性能影响,分析验证前池的面积和体形布置的合理性;提出泵站运行时各种工况下的前池水位控制方式;优化前池特征运行水位,提高最低运行水位,从而提高水泵机组的安装高程,减少前池、主副厂房等主体建筑物的工程量和工程投资。 To meet the special demand of Hui-Nan-Zhuang Pump station which has a big flow capacity , a high pump lift and a wide flow and head range, it is necessary to carry out computational fluid dynamics analyses and physical model test to recognize fluid state of the forebay of Hui-Nan-Zhuang Pump station, through which we can find some rules to avoid any bad effect to the pump ,and help us verify the rationality of the forebay conformation,and also we can optimize and decide characteristic water level to suit any case, that is a key function to pump erection elevation which decide civil quantity and cost.
出处 《南水北调与水利科技》 CAS CSCD 2008年第1期185-193,共9页 South-to-North Water Transfers and Water Science & Technology
基金 南水北调中线工程京石段应急供水工程(北京段)惠南庄泵站工程项目(编号9423)
关键词 泵站 进水前池 水力仿真分析 水工模型试验 特征水位 pump station forebay computational fluid dynamics analyses physical model test characteristic water level