期刊文献+

LOM and HOM damping study in a superconducting deflecting cavity for ALS at LBNL

LOM and HOM damping study in a superconducting deflecting cavity for ALS at LBNL
原文传递
导出
摘要 Superconducting deflecting cavities can be used in synchrotron light source to generate subpicosecond X-ray pulses while the impedance of the lower order modes (LOM) and higher order modes (HOM) in the cavity should be kept below an accepted level to avoid beam instability. These modes can be damped by adding waveguide on beam pipe. Detailed simulation of Q in CST Microwave Studio is introduced and experiment results on an aluminum model cavity with damping waveguide are reported to make a comparison. Superconducting deflecting cavities can be used in synchrotron light source to generate subpicosecond X-ray pulses while the impedance of the lower order modes (LOM) and higher order modes (HOM) in the cavity should be kept below an accepted level to avoid beam instability. These modes can be damped by adding waveguide on beam pipe. Detailed simulation of Q in CST Microwave Studio is introduced and experiment results on an aluminum model cavity with damping waveguide are reported to make a comparison.
出处 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2008年第3期205-208,共4页 中国物理C(英文版)
基金 Supported by NSFC(10775080)
关键词 deflecting cavity lower order mode impedance calculation HOM damping deflecting cavity lower order mode impedance calculation HOM damping
  • 相关文献

参考文献10

  • 1Zholents A et al. NIM A . 1999
  • 2Robin D et al.Generation of Picosecond X-Ray Pulses in the ALS Using RF Orbit Deflection[].Proceedings of PAC.2005
  • 3Shi J et al.A Three-Cell Superconducting Deflecting Cav- ity Design for the ALS at LBNL[].Proceedings of PAC.2005
  • 4Hosoyama K et al.Superconducting Crab Cavity for KEKB[].Proceedings of APAC.1998
  • 5CHAO A W.Physics of Collective Beam Instabilities in High Energy Accelerators[]..1993
  • 6Akai K,Funakoshi Y.Beam-Loading Issues and Require- ments for the KEKB Crab RF System[].Proceedings of EPAC.1996
  • 7Kwiatkowski S,Baptiste K,Julian J.New Waveguide-Type Hom Damper for ALS Storage Ring Cavities[].Proceed- ings of EPAC.2004
  • 8LI D et al.RF Deflecting Cavity Design for Berkeley U1- trafast X-Ray Source[].Proceedings of EPAC.2002
  • 9Browman M J.Using the Panofsky-Wenzel Theorem in the Analysis of Radio-Frequency Deflectors[].Proceedings of PAC.1993
  • 10Shi J et al.Comparison of Measured and Calculated Cou- pling between a Waveguide and an RF Cavity Using CST Microwave Studio[].Proceedings of EPAC.2006