通过对反应温度、压力、液体空速、空气/水比及原水pH值诸工艺条件的考察,确定催化湿式氧化处理含氨和高COD值的焦化污水的最佳工艺条件为270℃,9.0MPa,空气/水(体)=210∶1,原水pH=9.8,液体空速=2.0h-1。在该条件下所研制的催化剂对CODCr及NH3-N的去除率分别达到99.6%,经处理的焦化污水水质优于国家环保排放标准的要求。
Reaction conditions of Catalytic Wet Oxidation Process used for treatment of coke oven wastewater containing high concentration of ammonia and COD are studied. The decomposition rate of COD and NH 3 N decreases with increase of space velocity of wastewater and decrease of reaction pressure. Under a fix pressure the decomposition rate of COD and NH 3 N increases with the increase of temperature through a maximum value then decreases. At the best reaction conditions:T=210∶1(Volume),pH=9.8,the decomposition rate of COD and NH 3 are 99.1% and 99.6% respectively with the catalyst prepared by us.
出处
《水处理技术》
CAS
CSCD
1997年第3期160-164,共5页
Technology of Water Treatment
关键词
有机废水
湿式氧化
COD
净化
废水处理
Treatment of Organic Wastewater, Wet Oxidation Reaction, Revomal of COD, Revomal of NH 3 N.