提出了一种荧光灯单镇流器双灯管串联节电电路的试验设计,并介绍了元件参数计算选用方法。理论计算和试验均表明,该配套工作方式比传统的一只镇流器配一只灯管的工作方式可节省镇流器能耗50%以上,功率因数成倍提高,还可节省一只镇流器。经实际试验,其性能良好,以此原理制造日光灯具可大量节能且经济效益显著,值得进一步推广。
This paper repers to a new fluorescent lamp energy saving method ——single ballast two tubes series circuit and introduces the caculative method of selecting parameter of elenent. Theory calculation and experiment indicate that: The method of sihgle ballast saves the energy above 50 % then the common circuit of one ballast with a tube and the power factor being doubled. To manufacture fluorescent lamps and lanterns with this circuit will save energy and very economy largely, so, it's worth to research and spread this circuit.
出处
《中国照明电器》
2008年第1期21-24,共4页
China Light & Lighting
关键词
日光灯
灯管串联电路
电路设计
节能
fluorescent lamp
tubes series circuit
circuit design