期刊文献+

自动测试系统视情计量保障方法研究 被引量:3

Study on Condition-Based Metrology Method for Automatic Test Systems
下载PDF
导出
摘要 针对传统计量保障方式容易导致不足计量和过剩计量的问题,提出了自动测试系统的视情计量保障方法.规划了自动测试系统的视情计量保障体系;进行了自动测试系统的溯源性设计;分析了校准数据的特征;建立了校准间隔优化模型;并且在两次校准间隔期内采用测量过程控制方法,全面监控自动测试系统的量值状态.实验表明,自动测试系统的视情计量保障在一定程度上缓解了不足计量和过剩计量的矛盾,提高了计量保障效率. For the problems of lack calibration and superfluous calibration caused by traditional metrology and assurance ways, a condition-based metrology method for automatic test systems was proposed. Firstly, the system of condition-based metrology was established. Then, according to calibration requirements of automatic test systems, the traceability design was presented. After historical calibration data were analyzed, calibration interval optimization models were proposed. Furthermore, the measurement process control was also used during two calibration's intervals to monitor quality values. Experiments show that the condition-based metrology improves the metrological efficiency of automatic test systems.
出处 《测试技术学报》 2008年第1期24-30,共7页 Journal of Test and Measurement Technology
关键词 自动测试系统 视情计量保障 溯源性设计 校准间隔优化 测量过程控制 automatic test system condition-based metrology traceability design calibration interval optimization measurement process control
  • 相关文献

参考文献15

  • 1于劲松,李行善.美国军用自动测试系统的发展趋势[J].测控技术,2001,20(12):1-3. 被引量:53
  • 2Albright J D. Reliability Enhancement of the Navy Metrology and Calibration Program[R], ADA341394, 1997.
  • 3王振魁.浅谈国防军工计量科学的发展趋势[J].宇航计测技术,2001,21(4):57-64. 被引量:3
  • 4高占宝,梁旭,李行善.ATE系统校准技术研究[J].电子测量与仪器学报,2005,19(2):1-5. 被引量:35
  • 5ISO 10012:2003 Measurement management systems-Requirements for measurement processes and measuring equipment[S], 2003.
  • 6ISO 10012 Partl. Quality assurance requirements for measuring equipment metrological confirmation system for measuring equipment[S], 1992.
  • 7Kuo Huang Lin, Bin Da Liu. A gray system modeling approach to the prediction of calibration intervals[J]. IEEE Transactions on Instrumentation and Measurement, 2005, 54(1): 297-304.
  • 8赵瑞贤.巡回计量综合保障关键技术及实现方法研究[D].北京:北京航空航天大学,2005:12.
  • 9ISO 10012 Part2. Quality assurance requirements for measuring equipment measurement process control[S], 1993.
  • 10Hillier F S. X-R chart control limits based on a smail number of subgroups[J]. Journal of Quality Technology, 1969, 1(1): 17-26.

二级参考文献31

  • 1朱慧明,韩玉启.基于随机参数的贝叶斯统计质量控制模型[J].南京理工大学学报,2004,28(4):445-448. 被引量:5
  • 2李志强,杨铁忠,陈怀艳.军事装备技术保障中的计量确认和测量过程控制方法研究[J].电子测量与仪器学报,2004,18(3):1-7. 被引量:4
  • 3徐志坚,孟晓风,边泽强.便携式多功能检定仪设计[J].测控技术,2005,24(8):60-63. 被引量:5
  • 4赵瑞贤.巡回计量综合保障关键技术及实现方法研究.北京:北京航空航天大学,2005.
  • 5[1]ISO 10012:2003 Measurement Management Systems-Requirements for Measurement Processes and Measuring Equipment[S],2003.
  • 6IEEE Standard 1226.3 - 1998, IEEE Trial-Use Standard for a Board Based Environment for Test( ABBET), Overview and Architecture [ S ].
  • 7IVI Foundation. IVI signal interface, functional specification, Rev. 0.3 [ Z ]. 2000-10.
  • 8李宝安.[D].北京:北京航空航天大学,2003-01.
  • 9WitteRA 何小平译.电子测量仪器—原理与应用[M].北京:清华大学出版社,1995..
  • 10Gao Zhanbao, Li Xingshan. Practical calibration methods for VXIBus Instrumentation, 5th International Symposium on Instrumentation and Control Technology, 2003,10.

共引文献96

同被引文献17

引证文献3

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部