期刊文献+

甲状腺肿触诊法可靠性辩析 被引量:7

Analysis on reliability and validity for goiter palpation
下载PDF
导出
摘要 三位医生分别对255名儿童进行了甲状腺触诊检查,A医生检出率为15.69%,B医生为30.59%,C医生为21.57%。A与B医生甲肿率符合度(Kappa值)是0.32,A与C医生符合度是0.40,B与C医生符合度是0.25,重复性差,可信程度低。三位医生触诊与“B超”检查结果比较,符合度分别为A医生0.21,B医生0.11,C医生0.14,符合度很低,真实性很差。作者对研究结果做了扼要讨论,并提供了相应的建议。 This paper reported the results of thyroid examination for 255 children by three doctors and the palpation results were compared with ultrasound.The goiter rate reported by Doctor A is 15.96%,Doctor B is 30.59%,and Doctor C is 21.57%,respectively.The concordances(Kappa Value) among the three doctors are low(Kappa=0.25 ̄0.40),indicating that the reliability of palpation method is low .The concordances between each of the three doctors and B ultyrasonography are very low (Kappa=0.11 ̄0.21),suggesting that the validity of the palpation is very poor.The results are discussed briefly,and suggestion is made by the authors.
出处 《中国地方病学杂志》 CAS CSCD 1997年第3期139-142,共4页 Chinese Jouranl of Endemiology
基金 卫生部科学研究基金
关键词 甲状腺肿 流行病学 触诊 B超 超志波诊断 Goiter\ Epidemiology\ Palpation\ B Ultrasound