摘要 紫外辐射一般较弱,在大气中传输衰减较厉害,提高光电阴极量子效率是紫外探测技术的关键。通过对不同基底上光电阴极的分析和实验,得出以MCP为基底的光电阴极在发射模式为反射式时,量子效率高﹑制作工艺简单。并确定了CsI光电阴极厚度与MCP的规格参数的关系。 The ultraviolet radiation usually is weak ,and its attenuation of atmospheric transmission is grisliness, so improving the quantum efficiency is the key to the ultraviolet detecting technology ,by means of experiments and analyzing of the photocathode CsI on different substrate ,induced when the photocathode CsI is on MCP substrate and emitting mode is reflection ,the quantum efficiency is higher, the craft of facture is predigested Foremost,ascertained the relationship ofphotocathode CsI' s thickness and MCP specifications parameter.
出处 《咸阳师范学院学报》 2007年第6期22-25,共4页 Journal of Xianyang Normal University
关键词 量子效率 MCP基底 反射式 亮度 quantum efficiency MCP substrate reflecting mode luminance
  • 相关文献

参考文献9

  • 1Danks A C Joseph C Bybee R Argabright .V.Abraham.J. Kimble. R.and Woodgate B Proceedings of ESA Symposium on Photon Detectors for Space Instruments ESA ESTEC Noordwijk[J].Netherlands.ESA SP,2000,35(6):269.
  • 2A,Bream,C.j oram,F.Piuz, E.Schyns, J.Seguinot. Technology of photocathode production[J]. NucLinstr.Meth.A,2002,47(8): 400.
  • 3Joseph C L Argabright V .Bybee.R.Danks. A. and Woodgate. B..Proc.SPIE[J]. Ultraviolet Technology V, 1994,82(22): 116.
  • 4Joseph.SPIE Photodetectors[J].Materials and Devices Ⅱ,1997, 99(29):39.
  • 5严增濯.紫外和红外真空电子器件及其应用[J].真空电子技术,1994,7(6):34-40. 被引量:1
  • 6李佳,庞其昌,彭文达,李宏云,阎国安,高春建.选通式象增强器的新型导电基底[J].光子学报,2000,29(9):861-864. 被引量:10
  • 7赵宝升,王俊锋,桂建保.脉冲X射线源的获取及门控成像[J].光子学报,2003,32(12):1450-1452. 被引量:6
  • 8A.T.Kenter.J.It.chappel.K.Kobagashi. Performance and calibration of the AXAF High Resolution Camera I [J].Imaging Readout.SPIE, 1997,31 (4).
  • 9Ryoji Enomoto,Takayuki.Sumiyoshi.Test of various photocathode[J]. Nucl.Instrum.Meth., 1994,34(3): 117.

二级参考文献6

  • 1Andre Egbert,Boris N.Chichkov,et al.Femtosecond laser-driven X-ray tube.Opt Eng,2002,41(10):2658~2667
  • 2Gordon C L,Yin G Y,et al.Time-gated imaging with an ultrashort-pulse,laser-produced-plasma X-ray source.Opt Lett,1995,20(9):1056~1058
  • 3Gratz M,Kiernan L,et al.Time-gated X-ray tomography.Appl Phys Lett,1998,73(20):2899-2901
  • 4Tillman C,Mercer I,et al.Elemental biological imaging by differential absorption with a laser-produced X-ray source.J Opt Soc Am(B),1998,13(1):209~215
  • 5徐华盛,孙键,申屠军.门控微通道板光电倍增管组件[J].光电子技术,1999,19(2):112-116. 被引量:4
  • 6赵宝昇,王治平.X射线像增强器象质评价[J].高速摄影与光子学,1991,20(3):292-299. 被引量:8

共引文献14

同被引文献25

引证文献2

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部