期刊文献+

1025t/h 四角切圆锅炉炉膛出口烟温偏差研究 被引量:5

Flue Gas Temperature Deviation at the Exit of 1 025t/h Boiler Furnace with Tangential Firing
下载PDF
导出
摘要 在多台锅炉烟温偏差研究的基础上,系统地分析了四角切圆锅炉炉膛出口水平烟道烟温偏差形成的机理、影响因素和对策;认为炉膛出口残余旋转所形成的烟速偏差是烟温偏差形成的根本原因,炉膛结构、煤质和燃烧工况等因素影响烟温偏差,给出了1025t/h锅炉烟温偏差与各主要影响因素的相关曲线,并指出了改善和消除烟温偏差的有效手段。 Based upon the study of flue gas temperature deviation of several boilers,the forming mechanism,influencing factors and countermeasures of flue gas temperature deviation in the horizontal duct behind the exit of boiler furnace with tangential firing are systematically analyzed;it is thought of that,the flue gas velocity deviation caused by the remaining turning at the exit of furnace is the fundamental reason for flue gas temperature deviation forming,and furnace structure,coal quality and combustion condition etc. factors influence flue gas temperature deviation as well.The relationship curves between flue gas temperature deviation of 1 025t/h boiler and major influencing factors are given and also the effective measures for improving and eliminating flue gas temperature deviation are indicated.
出处 《中国电力》 CSCD 北大核心 1997年第6期3-5,共3页 Electric Power
关键词 四角切圆锅炉 烟温偏差 炉膛出口烟道 锅炉 tangential firing boiler flue gas temperature deviation influencing factors
  • 相关文献

参考文献1

二级参考文献4

  • 1张才根,邵国桢,陈力.1025吨/时单锅膛直流锅炉对流烟道水模试验[J]锅炉技术,1988(09).
  • 2张才根,薛林德,孙渝生,唐开元,张自栋,李梦实.1000吨/时锅炉水平烟道流场分布测量的分析[J]锅炉技术,1984(08).
  • 3张才根,薛林德.1000吨/时燃煤锅炉水平烟道沉灰原因和改进措施的探讨[J]锅炉技术,1983(10).
  • 4张才根,庄文贤.锅炉两侧烟温差的起因及改善措施探讨[J].锅炉技术,1992(2):1-7. 被引量:13

共引文献7

同被引文献31

引证文献5

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部