摘要
HG1021/18.2型锅炉2台动叶调节轴流式引风机多次出现断叶片事故,针对这个问题做了多项试验研究,根据试验结果,综合分析了其中1台风机发生多次动叶片断裂的原因,并提出了防止该风机断叶片的改进意见。
On the basis of testing and research results of two axial folw induced draft fans with moving blade regulation, the causes of repeated moving blade cracks are comprehensively analyzed and the improvement proposals for preventing such type induced draft fans from blade cracking are put forward.
出处
《中国电力》
CSCD
北大核心
1997年第6期10-15,共6页
Electric Power
关键词
锅炉
引风机
断叶事故
技术分析
power plant axial flow draft fans blade cracks