期刊文献+

Toxicity assessment of heavy metals and organic compounds using CellSense biosensor with E.coli 被引量:15

Toxicity assessment of heavy metals and organic compounds using CellSense biosensor with E.coli
下载PDF
导出
摘要 A new strategy using an arnperometric biosensor with Escherichia coli (E. coli) that provides a rapid toxicity determination of chemical compounds is described. The CellSense biosensor system comprises a biological component immobilized in intimate contact with a transducer which converts the biochemical signal into a quantifiable electrical signal. Toxicity assessment of heavy metals using E.coli biosensors could be finished within 30 min and the 50% effective concentrations (ECso) values of four heavy metals were determined. The results shows that inhibitory effects of four heavy metals to E.coli can be ranked in a decreasing order of Hg^2+ 〉 Cu^2+ 〉 Zn^2+ 〉 Ni^2+, which accords to the results of conventional bacterial counting method. The toxicity test of organic compounds by using CellSense biosensor was also demonstrated. The CellSense biosensor with E. coli shows a good, reproducible behavior and can be used for reproducible measurements. A new strategy using an arnperometric biosensor with Escherichia coli (E. coli) that provides a rapid toxicity determination of chemical compounds is described. The CellSense biosensor system comprises a biological component immobilized in intimate contact with a transducer which converts the biochemical signal into a quantifiable electrical signal. Toxicity assessment of heavy metals using E.coli biosensors could be finished within 30 min and the 50% effective concentrations (ECso) values of four heavy metals were determined. The results shows that inhibitory effects of four heavy metals to E.coli can be ranked in a decreasing order of Hg^2+ 〉 Cu^2+ 〉 Zn^2+ 〉 Ni^2+, which accords to the results of conventional bacterial counting method. The toxicity test of organic compounds by using CellSense biosensor was also demonstrated. The CellSense biosensor with E. coli shows a good, reproducible behavior and can be used for reproducible measurements.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第2期211-214,共4页 中国化学快报(英文版)
基金 supported by the National Natural Science Foundation of China(No.20707014) the Program for Young Excellent Talents of Tongji University.
关键词 Whole-cell biosensor Heavy metal Organic compounds TOXICITY Whole-cell biosensor Heavy metal Organic compounds Toxicity
  • 相关文献

参考文献13

  • 1[1]L.Manusad(z)ianas,L.L.Balkelyte,et al.Aquat.Toxicol.63 (1)(2003)27.
  • 2[2]T.Reemtsma,Anal.Chim.Acta 426 (2001)279.
  • 3[3]M.D.Hernando,Fernández-Alba,et al.Talanta 65 (2)(2005)358.
  • 4[4]S.Rodriguez-Mozaz,M.J.López de Alda,et al.Talanta 65 (2)(2005)291.
  • 5[5]J.Jensen,L.E.Sverdrup,Ecotox.Environ.Safe.52 (2002)75.
  • 6[6]V.L.K Jennings,M.H.Rayner-Brandes,D.J.Bird,Water Res.35 (14)(2001)3448.
  • 7[7]K.C.G.Straud,D.B.Jones,Water Treat.Exam.24 (1975)100.
  • 8[8]J.Kumar,S.Kumar Jha,S.F.D'Souza,Biosens.Bioelectron.21 (11)(2007)2100.
  • 9[9]D.Liu,Bull.Environ.Contam.Toxicol.26 (1981)145.
  • 10[10]A.AJ.Torriero,E.Salinas,et al.Anal.Chim.Acta 71 (3)(2007)1198.

同被引文献113

引证文献15

二级引证文献65

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部