期刊文献+

直流单极-大地方式谐波特性及其对交流保护影响的分析 被引量:8

Harmonic characteristics of power transformer for DC bias and its impact on power system protection
下载PDF
导出
摘要 直流输电系统单极-大地运行方式对交流电网继电保护产生影响的根源在于直流偏磁导致电力变压器谐波以及电流互感器传变特性的变化,基于PSCAD/EMTDC电磁暂态仿真程序对直流偏磁下的变压器谐波特性以及保护用电流互感器传变特性进行了全面的仿真分析,得出相应的变化规律与特点,并以此为基础分析和评估了直流输电系统单极-大地运行方式对交流电网保护的影响。 The monipolar ground circuit operation mode of HVDC system results in the DC bias of power transformers and current transformers in AC power system. It causes the harmonics generated from power transformer and changes the transforming characteristics of CT. Harmonic characteristics of power transformer and transforming characteristics of CT for DC bias are fully studied in the paper by simulation using PSCAD/EMTDC software. The results are used to evaluate the impact on power system protection.
出处 《继电器》 CSCD 北大核心 2008年第4期5-9,41,共6页 Relay
基金 国家自然科学基金重点项目(50339010) "十一五"国家科技支撑计划重大项目资助(2006BAA02A30)~~
关键词 直流输电 直流偏磁 交流保护 谐波 HVDC DC bias harmonics protective relaying