期刊文献+

上消化道动态多生理参数记录分析技术的研究 被引量:1

Study on the Dynamic Multi Parameter Recording and Analyzing Technology for Upper Digestive Tract
下载PDF
导出
摘要 研制了1种新的用于上消化道功能疾病研究诊断的动态多生理参数记录分析系统.此系统借助置于体内的传感器导管和便携式记录盒,对胃酸、食道酸、心电进行24h动态连续记录监测,记录结束后,将数据传输给计算机进行分析.文章论述了传感器、记录器、数据分析等关键技术;给出了新研制的多参数集成的传感器导管的原理、结构及性能;介绍了记录器的结构和功能;讨论了数据分析、信号处理的方法和过程.胃液抽取法和动态监测法对照的动物实验证实了技术的可靠性. A new dynamic multi parameter recording and analyzing system is developed for the diagnosis of functional diseases in upper digestive tract. This system records stomach acidity, esophageal acidity and electrocardiogram simutenously and dynamically, under normal physiological conditions. The key techniques are discussed. The structure and character of a new developed micro multi parameter transducer probe are presented; the recorder and data analysis are also described in detail. Animal experiments and clinical applications show that this technique is valuable in the research on the digestive physiology and the diagnosis of functional diseases such as non cardiac chest pain.
出处 《西安交通大学学报》 EI CAS CSCD 北大核心 1997年第9期52-57,共6页 Journal of Xi'an Jiaotong University
基金 国家"八五"科技攻关项目 国家科委资助
关键词 监测 功能性疾病 数据记录 上消化道 生理参数 dynamic multi parameter monitoring digest fuctional diseases
  • 相关文献

参考文献2

  • 1龚均,陕西医学杂志,1996年,25卷,9页
  • 2许锡铭,生物医学换能器.原理与应用(译),1984年,278页

同被引文献24

  • 1皮喜田,彭承琳,郑小林,崔建国,侯文生,唐伟,樊华,吴旭东,刘洪英,刘洋.用于人体药物吸收研究的定点释放药丸系统研制[J].中国生物医学工程学报,2004,23(6):579-582. 被引量:10
  • 2Business Briefing:Pharmatech. The Role of Human Drug Absorption Studies in Development Pharmaceutics[ R ]. 2003.
  • 3Wilding I,Hirst P,Connor A. Development of a New Engineering-Based Capsule for Human Drug Absorption Studies[J]. Phamaceutical Science & Technology teday,2000,3(11 ) :385-391.
  • 4Wilding I, Prior D. Remote Controlled Capsules in Human Drug Absorption( HDA ) studies [ J ]. Critical Reviews in TherapeuticDrug Carrier Systems, 2003,20 ( 6 ) :405 -431.
  • 5Steinke F,Andra W,Heide R,et al. Rotating Magnetic Microspheres as Heating Mechanism for Remote Controlled Drug Release [ J ]. Jottmal of Magnetism and Magnetic Materials ,200'7,3 ( 11 ) :216-218.
  • 6Cao X,Lai S,James L,et al. Design of Self-Regnlated Drug Delivery Device[J]. Biomedical Micro devices,2001,3(2) :109-118.
  • 7刘建斌 蒋大宗.消化道pH值无线电遥测系统.生物医学工程学杂志,1988,5(1):39-43.
  • 8皮喜田,刘洪英,周承文,等.释药微电子胶囊[P].中国专利,2006100953544.2007-07-18.
  • 9Murata N. Physiological Signal Transmitter for Use Inside the Body [ P]. US Patent,3682160. 1969-10-16.
  • 10Mccaffrey C, Chevalefias O, O' mathuna C, et al. Swallowable Capsule Technology[ J]. IEEE Pervasive Computing,20og,7 (1) :23- 29.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部